Journal of Histochemistry and Cytochemistry Priciples for Free Access to Science
  Search:   
    >> Advanced Search

Guidelines | Subscriptions | About | exPRESS - Current - Archive | Business Information | Contact
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Deelder, A. M.
Right arrow Articles by de Water, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Deelder, A. M.
Right arrow Articles by de Water, R.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

A comparative study on the preparation of immunoglobulin-galactosidase conjugates

AM Deelder and R de Water

For the application of beta-D-galactosidase-immunoglobulin conjugates in the enzyme-linked immunosorbent assay (ELISA), four techniques for the preparation of such conjugates were compared. Sheep immunoglobulin (Ig) (against soluble egg antigens of the trematode Schistosoma mansoni) was coupled to beta-D-galactosidase by means of 1) glutaraldehyde treatment, 2) the heterobifunctional reagent N- succinimidyl 3-(2-pyridyldithio) propionate (SPDP), and 3,4) two different procedures using the coupling agent m-maleimidobenzoyl-N- hydroxysuccinimide ester(MBS). The prepared conjugates were then fractionated by gel filtration on Sepharose 6B and the resultant molecular weight fractions were tested in an ELISA for the detection of S. mansoni antigen. Optimal results were obtained with a conjugate that was synthesized according to one of the two techniques using MBS. With this conjugate, 10(-9) g antigen/ml could still be detected in an ELISA with a chromogenic substrate, which was at least ten times as sensitive as with the other conjugates. Application of a fluorogenic substrate resulted in a lower detection level of 10(-10) g antigen/ml.

Volume 29, Issue 11, pp. 1273-1280, 11/01/1981
Copyright © 1981 by The Histochemical Society


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?





Guidelines | Subscriptions | About | exPRESS - Current - Archive | Business Information | Contact
The Journal of Histochemistry & Cytochemistry is owned, published, and licensed by The Histochemical Society © 1981